Key takeaways
- There is no single legal capacity figure for most restaurants; your safe number comes from your own fire risk assessment, which you must carry out and keep under review.
- Capacity is limited by whichever runs out first: floor space, exit width, travel distance to exits or a cap in your premises licence.
- A standing reception holds far more people than a seated dinner in the same room, so set a capacity for each layout.
- Watch three thresholds: 60 and 300 people in the Home Office assembly guidance, 200 for Martyn's Law and under 500 for a temporary event notice.
Who decides your capacity
In England and Wales the person in control of the premises is the 'responsible person' for fire safety: the employer, owner, occupier or anyone else with control[1]. That person must carry out a fire risk assessment, review it regularly and put suitable fire safety measures in place. If you do not follow fire safety rules you could be fined or go to prison[1]. Scotland and Northern Ireland have their own fire safety laws, but the method is similar.
The local fire and rescue service does not hand most restaurants a number. Your capacity is a figure you work out, write down and can justify. A few venues also have a capacity condition in their premises licence, and that cap applies on top of the fire figure. The Home Office guide for places of assembly warns that licence limits may not be directly related to fire safety, so you need to know both[2].
Three numbers to work out for every room
Capacity is the lowest of three calculations. Do each one for every room and every layout you sell.
Floor space
For seated layouts the number of seats sets the figure. For unseated areas, foyers and bars, the Home Office guidance suggests estimating 0.3 to 0.5 square metres per person[2]. Measure the clear floor area once furniture, the bar, the DJ booth and the buffet are in place, not the empty room.
Exit capacity
Count the exits people can use and measure their clear width. The guidance says a route at least 750mm wide can take up to 100 people in normal-risk premises, and one at least 1,050mm up to 200[2]. Assume one exit may be blocked by fire and see whether the rest still cope.
Travel distance
Check how far guests must walk to reach an exit. The same guide sets suggested travel distances by risk, and longer routes or a single direction of escape reduce what is safe.
- Higher risk
- Normal risk
- Lower risk
Source: Home Office, 2024[2]
Show the data
| Item | Higher risk | Normal risk | Lower risk |
|---|---|---|---|
| At least 750mm wide | 80 | 100 | 120 |
| At least 1,050mm wide | 160 | 200 | 240 |
Risk level matters. Candles on every table, a smoke machine, a crowded dance floor or a basement room push you towards the higher-risk figures. Good alarm coverage, staff trained to evacuate and clear routes support the normal-risk figures.
Seated, buffet and standing are different numbers
The same room can hold very different numbers depending on how it is set. Write down a figure for each configuration and give it to whoever quotes events.
| Layout | Limiting factor | Capacity | Notes |
|---|---|---|---|
| Seated dinner, round tables | Seats and aisle widths | 60 | Keep 1.2m between table edges for service routes |
| Long banquet tables | Seats | 70 | Check the far end can still reach an exit |
| Buffet with some seating | Floor space and queue area | 80 | Place the buffet away from exit routes |
| Standing reception | Exit width | 120 | Two exits; one alone would cap the room lower |
| Standing with DJ and dance floor | Exit width at higher risk | 95 | Lower risk rating applied for lighting and density |
If a client asks for more than your sheet allows, the answer is a different layout or a different room, not a tighter squeeze. The final numbers deadline is a good point to check the headcount against the sheet.
Thresholds that change the rules
Some numbers bring extra duties regardless of your fire calculation.
- 60 and 300 people: the Home Office guide treats places of assembly holding up to 60 people as small and up to 300 as medium[2]. Above that, larger-venue guidance and more formal fire engineering apply.
- 200 people: under Martyn's Law (the Terrorism (Protection of Premises) Act 2025), premises where at least 200 people may be present are in scope, and 800 or more are enhanced tier[3]. The Act has an implementation period of at least 24 months from Royal Assent on 3 April 2025[4], so use the time to write simple public protection procedures.
- Under 500 people: a temporary event notice can authorise licensable activities for an event with fewer than 500 people at all times, including staff[5]. That limit includes your team, which catches out venues planning a 490-guest party.
Temporary event notices are common: an estimated 149,600 were given in England and Wales in the year to March 2026[6]. A TEN must be given at least ten clear working days before the event for a standard notice, and a single premises can have up to 15 a year, covering no more than 21 days in total[5]. A TEN covers licensable activities; it does not raise your fire capacity.
Licence conditions and why they bite
There were an estimated 227,300 premises licences in England and Wales at 31 March 2026[7]. Most say nothing about headcount, but some carry conditions on capacity, door staff above a set number or the use of certain rooms. Read yours before you quote a large event. Breaching conditions can lead to a review: of 542 premises licences reviewed in the year to March 2026, 46% were revoked or withdrawn[8]. That is the cost of getting it wrong in a busy December.
Mistakes that quietly cut your safe number
Most capacity problems are not about the headline figure but about what changes on the night. These are the ones fire officers and licensing teams see most often in restaurants and pubs.
- Extra furniture: a hired photo booth, a gift table or a stack of high chairs in front of a fire door narrows the exit and lowers the capacity of the whole room.
- Locked or chained exits: a side door locked to stop smokers wandering out is an exit you no longer have.
- Overflow into corridors: guests spilling out to queue for the toilets block the escape route other rooms rely on.
- Counting only guests: forgetting the band, the photographer, the caterer's team and your own staff.
- Two events, one stairway: a function upstairs and a busy restaurant below often share the same route out. Plan for both at once.
- Temporary structures: marquees, gazebos and pop-up bars bring their own fire risk and need their own assessment.
Plan for guests who need help to leave
Your capacity figure assumes everyone can walk out. At events this is often not true: older relatives at a birthday, a wheelchair user at an awards dinner, a guest on crutches. The responsible person must plan for emergencies and give staff the training they need[1], and that includes guests who need help. Ask about access needs on the booking form, seat those guests near a level exit, and name a member of staff to assist each one if the alarm sounds. For upstairs rooms without a level exit, discuss the plan with the organiser before the event rather than on the night.
A capacity checklist before every large booking
- Confirm the layout and pull the matching figure from your capacity sheet.
- Add staff, performers and suppliers to the guest count; they are people in the room too.
- Check every exit is unlocked, unobstructed and signed, and that no furniture narrows the route.
- Check whether the event takes the building over 200 people across all rooms at once.
- Check your premises licence conditions for capacity, door staff and hours.
- Brief staff on the evacuation route and who checks the toilets and back rooms.
- Keep a simple count at the door for standing events, with a clicker or tally.
Record it and review it
Capacity figures belong in your fire risk assessment, not in an events manager's head. Record how you reached each figure, the date and who did it. Review it after a refit, a new layout, new furniture or any near miss. If you are unsure, a competent fire risk assessor can check your calculations; for buildings that have changed use or layout, the guide points you back to building control and the design guidance[2]. When you know your safe numbers, you can sell events with confidence rather than guesswork, and plan your event staffing to match.
Frequently asked questions
Who sets the maximum capacity of a restaurant?
In most cases you do, through your fire risk assessment as the responsible person. Your premises licence may add a cap. The fire service can inspect and issue notices if the arrangements are not safe, but it rarely issues a number for an ordinary restaurant.
How many people can stand in a function room?
For unseated areas the Home Office guide suggests estimating 0.3 to 0.5 square metres per person, then checking exit widths and travel distances. The lowest of those results is your figure, and it is often the exits rather than the floor space that limit you.
Do staff count towards capacity?
Yes. Everyone in the building counts, including staff, performers and suppliers. For a temporary event notice the under-500 limit explicitly includes staff running the event.
Does Martyn's Law apply to my restaurant?
It applies to premises where at least 200 people may be present, so a larger restaurant, pub or venue hosting big events may be in scope. There is an implementation period before duties apply, so check the Home Office guidance and plan simple procedures now.
References
GOV.UK (2026). Fire safety in the workplace: your responsibilities (opens in a new tab) ↑
Home Office (2024). Fire safety risk assessment: small and medium places of assembly (opens in a new tab) ↑
Home Office (2025). Martyn's Law factsheet (opens in a new tab) ↑
Home Office (2025). Martyn's Law factsheet (opens in a new tab) ↑
GOV.UK (2026). Temporary events notice (opens in a new tab) ↑
Home Office (2026). Alcohol licensing, England and Wales, April 2025 to March 2026 (opens in a new tab) ↑
Home Office (2026). Alcohol licensing, England and Wales, April 2025 to March 2026 (opens in a new tab) ↑
Home Office (2026). Alcohol licensing, England and Wales, April 2025 to March 2026 (opens in a new tab) ↑